# J012--Fire Suppression System Maintenance and Kitchen Exhaust Cleaning

Notice 06fc59e2a5d1472cb623e8926c9db130 (solicitation 36C25027Q0078) from VETERANS AFFAIRS, DEPARTMENT OF, 250-NETWORK CONTRACT OFFICE 10 (36C250), posted 2026-11-06, responses due 2026-12-01T15:00:00.000Z. Status: open.

| Field | Value |
| --- | --- |
| Notice ID | 06fc59e2a5d1472cb623e8926c9db130 |
| Solicitation number | 36C25027Q0078 |
| Type | Solicitation |
| Agency | VETERANS AFFAIRS, DEPARTMENT OF |
| Sub-tier | VETERANS AFFAIRS, DEPARTMENT OF |
| Office | 250-NETWORK CONTRACT OFFICE 10 (36C250) |
| Posted | 2026-11-06T18:02:00.000Z |
| Response deadline (UTC) | 2026-12-01T15:00:00.000Z |
| Set-aside | Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) |
| NAICS | 811310 |
| PSC | J012 |
| Place of performance | Indianapolis, IN, USA |
| Award | - |

## Description

Fire Suppression System Maintenance and Kitchen Exhaust Cleaning Richard L Roudebush VA Medical Center 1481 West 10th Street, Indianapolis, Indiana 46202 Additional service location: 9045 East 59th Street, Building 402, Indianapolis, Indiana 46216 The Contractor shall maintain the identified fire suppression systems in a serviceable condition, remove grease accumulation from the complete identified kitchen exhaust systems, and maintain the Building 402 grease trap. The Contractor shall provide all labor, supervision, transportation, tools, access equipment, routine maintenance materials, cleaning supplies, waste handling, testing, service labels, and documentation required by this PWS. The recurring scope includes five kitchen fire suppression systems and five Kidde IND-21 Hazmat dry chemical systems, with monthly inspections of all ten systems, semiannual maintenance and service certification, and annual maintenance tasks. All five hoods require quarterly exhaust inspections and complete interior and exterior cleaning. The Building 402 grease trap requires quarterly inspection, pump-out, and cleaning. Appendix A identifies equipment and locations; Appendix B states service quantities, deliverables, and performance standards. The prime Contractor remains responsible for all subcontracted work and for submitting complete records directly to the COR. A kitchen cleaning report does not document fire suppression system maintenance, monthly suppression inspections, or grease-trap service; each service shall have its own identifiable record.

## Sources

- View on SAM.gov: https://sam.gov/opp/06fc59e2a5d1472cb623e8926c9db130/view
- Data as of 2026-11-14. Source: https://sam.gov/data-services/Contract%20Opportunities/datagov

## Cite this

"J012--Fire Suppression System Maintenance and Kitchen Exhaust Cleaning, SAM.gov contract opportunity 06fc59e2a5d1472cb623e8926c9db130." samgovapi.io, https://samgovapi.io/opportunity/06fc59e2a5d1472cb623e8926c9db130, data as of 2026-11-14. Primary record: https://sam.gov/opp/06fc59e2a5d1472cb623e8926c9db130/view

## API and MCP

- REST: GET https://samgovapi.io/api/v1/opportunities/06fc59e2a5d1472cb623e8926c9db130
- MCP tool: get_opportunity

Independent. Not affiliated with, endorsed by or sponsored by GSA, SAM.gov or any U.S. government agency. Registering in SAM.gov is free at sam.gov.

Get a free API key: https://samgovapi.io/sign-up?ref=ai-claudebot
