# LCMS

Notice 103641ae64874cfe8be78200849a8a39 (solicitation W911S226U2446) from DEPT OF DEFENSE, W6QM MICC-FT DRUM, posted 2026-01-14, responses due 2026-01-30T21:00:00.000Z. Status: open.

| Field | Value |
| --- | --- |
| Notice ID | 103641ae64874cfe8be78200849a8a39 |
| Solicitation number | W911S226U2446 |
| Type | Combined Synopsis/Solicitation |
| Agency | DEPT OF DEFENSE |
| Sub-tier | DEPT OF THE ARMY |
| Office | W6QM MICC-FT DRUM |
| Posted | 2026-01-14T18:00:03.000Z |
| Response deadline (UTC) | 2026-01-30T21:00:00.000Z |
| Set-aside | Small Business Set Aside - Total |
| NAICS | 334516 |
| PSC | 6630 |
| Place of performance | - |
| Award | - |

## Description

Require an instrument that contains both liquid chromatography and mass spectrometer in paired/joined configuration. The preferred system for the liquid chromatograph and the mass spectrometer should have all items manufactured and serviced by the same company. The integrated software package should be able to operate and control both the mass spectrometer and liquid chromatograph instruments from a single unified operating platform. The system should be capable of performing both qualitative and quantitative analysis on a sample in a single run. Instrument must include all software to process quantification data and acquire samples, automatically restarts upon power failure and detect asymmetry in peak shape for quality assurance/quality control. The instrument must use a dual ion source that can provide both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to the same sample. Desolvation capillary must be removeable and replaced without breaking vacuum which allows for easier maintenance. The detector must use an off axis, high energy conversion dynode coupled with a discrete multistage active film electron multiplier, without phosphorconversion. Maximum nitrogen consumption needs to be 15 L/min or less for nebulization and drying purposes. Autotuning function must be included that optimizes both positive and negative ion modes, all scan speeds, mass axis calibration, sensitivity, and mass resolution automatically with a single tuning solution. Must include a system check to provide essential information on the status of the instrument and can be integrated into batches for smooth maintenance and troubleshooting. Scan speed needs to be 15,000 u/sec in 0.1u steps without reducing scan mass range. Scan step resolution should be 0.7u at all scan speeds. Mass range must be from 2-2000 m/z to enable analysis of a wide range of analytes including large peptides with multi-charge states.Must include delivery and installation to West Point NY, 10996 and include a 1-year warranty on parts and labor.

## Sources

- View on SAM.gov: https://sam.gov/opp/103641ae64874cfe8be78200849a8a39/view
- Data as of 2026-11-13. Source: https://sam.gov/data-services/Contract%20Opportunities/datagov

## Cite this

"LCMS, SAM.gov contract opportunity 103641ae64874cfe8be78200849a8a39." samgovapi.io, https://samgovapi.io/opportunity/103641ae64874cfe8be78200849a8a39, data as of 2026-11-13. Primary record: https://sam.gov/opp/103641ae64874cfe8be78200849a8a39/view

## API and MCP

- REST: GET https://samgovapi.io/api/v1/opportunities/103641ae64874cfe8be78200849a8a39
- MCP tool: get_opportunity

Independent. Not affiliated with, endorsed by or sponsored by GSA, SAM.gov or any U.S. government agency. Registering in SAM.gov is free at sam.gov.

Get a free API key: https://samgovapi.io/sign-up?ref=ai-claudebot
