# Fire Suppression, Fire Alarm, Fire Sprinkler Systems Maintenance Service and Repair For Joint Base Lewis-McChord (JBLM) and Yakima Training Center (YTC), Washington

Notice 3a5cd71a69834f5a84f515bab95e4058 (solicitation W911S822R0002) from DEPT OF DEFENSE, W6QM MICC-JB LEWIS-MC CHORD, posted 2022-05-26, responses due 2022-06-06T19:00:00.000Z. Status: open.

| Field | Value |
| --- | --- |
| Notice ID | 3a5cd71a69834f5a84f515bab95e4058 |
| Solicitation number | W911S822R0002 |
| Type | Solicitation |
| Agency | DEPT OF DEFENSE |
| Sub-tier | DEPT OF THE ARMY |
| Office | W6QM MICC-JB LEWIS-MC CHORD |
| Posted | 2022-05-26T22:57:19.000Z |
| Response deadline (UTC) | 2022-06-06T19:00:00.000Z |
| Set-aside | 8(a) Set-Aside (FAR 19.8) |
| NAICS | 561621 |
| PSC | J012 |
| Place of performance | Joint Base Lewis McChord, WA, USA |
| Award | - |

## Description

The Contractor shall provide all personnel, equipment, tools, materials, supervision, and personnel services necessary to examine, restore, maintain, repair, clean, inspect, and test the following: installed facility fire sprinkler systems, kitchen fire suppression systems, fire pumps, fire pump monitoring devices and related equipment, fire sprinkler monitoring devices, aircraft hangar Aqueous Film Forming Foam (AFFF) systems (to include annual lab testing of the foam concentrate agent), automatic fire alarms, Fire Alarm Control Panels (FACP) including the software and associated devices, (activation, warning and auxiliary), and electrical/electronic components of the systems. The Contractor shall provide testing and programming to facilities with Mass Notification Systems (MNS). The Contractor shall provide updated Computer-Aided Design (CAD) (current year) drawings in a manner that will ensure fire systems serviceability and proper operation. Contractor shall provide a list of major component manufacturers and system components, year of installation as near as can be determined, as well as ITM cycle for sprinkler and suppression systems. Contractor shall submit reports to the Contracting Officers Representative (COR) at JBLM, Washington (WA) and leave a copy of the CAD drawing at the FACP in each building. All work shall comply with and be in accordance with (IAW) the Unified Facilities Criteria (UFC) 3-601-02 Operations and Maintenance: Inspection, Testing, and maintenance of Fire Protections Systems, National Fire Protection Association (NFPA) Standards 10 through 25, 70, 72, 96, JBLM requirements and the manufacturer’s instructions. The Unified Facilities Criteria (UFC) 3-601-02 shall take first precedence over other guidance. Technical Exhibit 1 (TE-1) shows the JBLM and YTC, WA facilities list. Technical Exhibit 2 (TE-2) shows the Kitchen Hood Listing.

## Sources

- View on SAM.gov: https://sam.gov/opp/3a5cd71a69834f5a84f515bab95e4058/view
- Data as of 2026-11-14. Source: https://sam.gov/data-services/Contract%20Opportunities/datagov

## Cite this

"Fire Suppression, Fire Alarm, Fire Sprinkler Systems Maintenance Service and Repair For Joint Base Lewis-McChord (JBLM) and Yakima Training Center (YTC), Washington, SAM.gov contract opportunity 3a5cd71a69834f5a84f515bab95e4058." samgovapi.io, https://samgovapi.io/opportunity/3a5cd71a69834f5a84f515bab95e4058, data as of 2026-11-14. Primary record: https://sam.gov/opp/3a5cd71a69834f5a84f515bab95e4058/view

## API and MCP

- REST: GET https://samgovapi.io/api/v1/opportunities/3a5cd71a69834f5a84f515bab95e4058
- MCP tool: get_opportunity

Independent. Not affiliated with, endorsed by or sponsored by GSA, SAM.gov or any U.S. government agency. Registering in SAM.gov is free at sam.gov.

Get a free API key: https://samgovapi.io/sign-up?ref=ai-claudebot
