# Chemical Storage Building

Notice 5895ed8ef5244952aaeec88d443ef15a (solicitation W911S226U3863) from DEPT OF DEFENSE, W6QM MICC-FT DRUM, posted 2026-08-24, responses due 2026-08-27T18:00:00.000Z. Status: open.

| Field | Value |
| --- | --- |
| Notice ID | 5895ed8ef5244952aaeec88d443ef15a |
| Solicitation number | W911S226U3863 |
| Type | Combined Synopsis/Solicitation |
| Agency | DEPT OF DEFENSE |
| Sub-tier | DEPT OF THE ARMY |
| Office | W6QM MICC-FT DRUM |
| Posted | 2026-08-24T18:31:52.000Z |
| Response deadline (UTC) | 2026-08-27T18:00:00.000Z |
| Set-aside | Small Business Set Aside - Total |
| NAICS | 332311 |
| PSC | 5670 |
| Place of performance | - |
| Award | - |

## Description

The chemical storage building must meet several specifications for construction, safety, and utility. The required minimum dimensions are 42 feet in length, 8 feet in width, and 8 feet 3 inches in height. Access shall be provided by a 60-inch by 80-inch set of double doors, with at least one 36-inch active leaf, centered on one of the 42-foot walls and secured with a padlock-compatible handle. For spill containment, the building must include a sump with a minimum capacity of 1200 gallons.The structure must feature a robust fire-rated design, with walls tested by Intertek for a minimum 4-hour rating and a roof tested for a minimum 3-hour rating. Electrical specifications include a 12-space, 100-amp NEMA 3R main breaker panel (120V/240V), two Class 1, Division 2 explosion-proof LED light fixtures with a switch for the interior, and a dust/vapor-resistant exterior light with a photocell installed outside the hazard zone. Ventilation will be handled by an explosion-proof exhaust system rated for 335 CFM or higher, suitable for petroleum-based storage and compliant with all NFPA/UFC codes, complete with an indicator light and an emergency shut-off switch.For safety and functionality, the building shall be equipped with a grounding kit including an 8-foot ground rod, 10 feet of cable, and a clamp. The interior will be furnished with three-tier, 5-foot-long shelves that are 14 inches deep with a 2-inch lip. A non-perforated, skid-resistant steel ramp, measuring at least 52 inches wide by 72 inches long, must be included. Additionally, the unit shall come with three 10-pound ABC dry chemical fire extinguishers: two installed inside on either side of the door, and one mounted outside in a weatherproof cabinet. The completed chemical storage building is to be delivered to Building P-91, Railroad Street, Fort Drum, NY 13602.

## Sources

- View on SAM.gov: https://sam.gov/opp/5895ed8ef5244952aaeec88d443ef15a/view
- Data as of 2026-11-14. Source: https://sam.gov/data-services/Contract%20Opportunities/datagov

## Cite this

"Chemical Storage Building, SAM.gov contract opportunity 5895ed8ef5244952aaeec88d443ef15a." samgovapi.io, https://samgovapi.io/opportunity/5895ed8ef5244952aaeec88d443ef15a, data as of 2026-11-14. Primary record: https://sam.gov/opp/5895ed8ef5244952aaeec88d443ef15a/view