# Tiny Home

Notice de6353616ab54a6080d93cd32b42b04d (solicitation W911S226U2309) from DEPT OF DEFENSE, W6QM MICC-FT DRUM, posted 2026-01-06, responses due 2026-01-14T16:00:00.000Z. Status: open.

| Field | Value |
| --- | --- |
| Notice ID | de6353616ab54a6080d93cd32b42b04d |
| Solicitation number | W911S226U2309 |
| Type | Combined Synopsis/Solicitation |
| Agency | DEPT OF DEFENSE |
| Sub-tier | DEPT OF THE ARMY |
| Office | W6QM MICC-FT DRUM |
| Posted | 2026-01-06T17:53:40.000Z |
| Response deadline (UTC) | 2026-01-14T16:00:00.000Z |
| Set-aside | Small Business Set Aside - Total |
| NAICS | 321991 |
| PSC | 5450 |
| Place of performance | - |
| Award | - |

## Description

Reason for amendment is to change the response date from 08 January 2026 to 14 January 2026, to allow additional time due to the holidays. Contractor shall provide a prebuilt modular home with a screened-in outdoor porch. Exterior dimensions not to exceed 13 feet 8 inched by 39 feet 7. inches Entrance to the building will be from the porch. Building to be built for 4-season use. Building exterior shall include the following (final colors to be determined at a later date, shall be selected from manufacturers standard selection), Standing seam metal roof, 5:12 pitch(with a factory applied finish), Engineered wood lap siding and trims, with textured finish and factory allied primer and finish, LED outdoor lighting near entryway, Insulated single hung low E vinyl windows without grid, Main entryway from porch to have lockable painted 6 panel steel entryway door with smart programmable smart lock, Provide electrical panel box in NEMA rated enclosure for 50 amp service, Insulated skirting, R11 or greater to be supplied along the building that will match building siding and will cover the underside of the building and span to grade. An access door is to be supplied on the skirting large enough to access the underbelly of the building. Building interior shall include the following: Kitchen to include 18 CF stainless steel refrigerator, full size gas range, space saver microwave, single bowl stainless steel drop-in sink, box-built cabinets with adjustable shelves, soft close dovetail drawers, 6-inch tile backsplash, and solid surface granite countertops (final finishes/colors to be determined at a later date, shall be selected from manufacturers standard selection), Full bathroom to include tile shower with glass door and shower road, china lavatory sink with metal faucets, 6-inch tile backsplash, elongated comfort height residential toilet, rainfall and handheld shower heads, and toilet paper holder and towel bar, 18k/24k fully electric split system unit for heating/cooling(one for master bedroom and one in living area, Interior walls and doors, sealed, 1.5 inch wood blinds throughout, 9-10 feet smooth finished ceiling, ? inch drywall with ? inch luan backer, ? inch vinyl plank flooring throughout(stock colors) Solid wood trim and moldings throughout, Furniture package to include sectional sofa for living area, single and double bed base and mattress for bunk room, queen bed base and mattress for master bedroom, and 42 inch wall mounted TV with swivel mounts in living area and master bedroom, Ceiling fan in living room centered with LED lights, Built in 4 drawer dressers in each bedroom, USBC outlets in each room, Nightstands on each side of bed in master bedroom, on demand gas water heater, Standard manifold plumbing system, Standard electrical package sufficient to power building appliances ? 50 amp service required, Deluxe overhead LED can lighting. Fire Protection Requirements: Provide all materials and equipment to include sprinkler system, fire alarm system, and perform all labor required to install complete and operable fire protection and health/safety systems in compliance with the most current editions of UFC 3-600-01, UFC 4-021-01, NFPA 13R, NFPA 24, NFPA 70, NFPA 72, NFPA 101, NFPA 90A, NFPA 10, and the additional standards referenced there in. General Design and Analysis: Provide a complete set of plans and specifications for all aspects of the fire protection design: This project requires the design, review, and oversight services of an FPE and as such the contractor is required to provide those services either directly or through a subcontract. The FPE shall be involved in every aspect of the design, construction, and testing/commissioning as it relates to fire protection and life safety. This includes, but is not limited to, building code analysis, life safety code analysis, design of automatic fire alarm, detection and suppression systems, water supply analysis, a multi-discipline review of the entire project, construction inspections and witnessing of fire protection acceptance testing/commissioning. The contractor shall submit with proposal, a written copy of the FPE resume indicating education, professional registration, and work experience, along with a letter attesting to their compliance with the requirements of this section. The letter must include an imprint of their professional engineering stamp with signature. Fire Protection Engineer Qualifications: The fire protection engineer of record shall be a registered professional engineer (P.E.) who has passed the fire protection engineering written examination administered by the National Council of Examiners for Engineering and Surveys (NCEES), with a minimum of 5 years experience, dedicated to fire protection engineering that can be verified with documentation. Evidence of qualifications shall be provided to the Government. In the design plans, include a fire protection design analysis, life safety plans, a code compliance summary sheet, code compliance site plan, and preliminary hydraulic analysis in accordance UFC 3-600-01. Final Design: The FPE must review the complete 100 percent design drawings and specification submission (all disciplines) and document in writing that the design complies with this UFC and all applicable fire protection and life safety design criteria. The review must provide verification that all items listed in the design analysis are correctly shown on the drawings and in the specification and list any approved equivalencies or deviations from this UFC. This design compliance document must be submitted prior to construction and must bear the signature and professional seal of the FPE. Fire Alarm and Detection Systems: Design and install fire alarm and mass notification systems as required to meet the required codes and standards. The design and installation shall be in accordance with UFC 3-600-01, UFC 4-021-01; NFPA 72, NFPA 101, NFPA 90A, NFPA 13, UFGS 28 31 76, and the Fort Drum Utility Standar

## Sources

- View on SAM.gov: https://sam.gov/opp/de6353616ab54a6080d93cd32b42b04d/view
- Data as of 2026-11-13. Source: https://sam.gov/data-services/Contract%20Opportunities/datagov

## Cite this

"Tiny Home, SAM.gov contract opportunity de6353616ab54a6080d93cd32b42b04d." samgovapi.io, https://samgovapi.io/opportunity/de6353616ab54a6080d93cd32b42b04d, data as of 2026-11-13. Primary record: https://sam.gov/opp/de6353616ab54a6080d93cd32b42b04d/view

## API and MCP

- REST: GET https://samgovapi.io/api/v1/opportunities/de6353616ab54a6080d93cd32b42b04d
- MCP tool: get_opportunity

Independent. Not affiliated with, endorsed by or sponsored by GSA, SAM.gov or any U.S. government agency. Registering in SAM.gov is free at sam.gov.

Get a free API key: https://samgovapi.io/sign-up?ref=ai-claudebot
